Home > HEATING & COOLING > FIREPLACES & STOVES > STOVE PIPE & ACCESSORIES > CHIMNEY PIPE ACCESSORIES
Sort By:
Page of 1
Ameri-Vent 8RSC Double Wall Round Storm Collar Ultra Temp 208450 Type A Locking Band Selkirk 206810 Storm Collar
Use with HS chimney roof flashing to insure water tight installation. Selkirk SURE-TEMP Locking Band, Stainless Steel, 8 in Dia, Suitable for: Chimney Pipe Designed to fit on the round chimney pipe just above the roof flashing. The upper edge of the collar should be waterproofed with plastic sealer to prevent any water from leaking between the collar and chimney pipe. Part is tightened with screws or tabs after proper positioning.
Selkirk 208810 Storm Collar Ultra Temp 207450 Type A Locking Band Selkirk 206480 Finishing Collar
Designed to fit on the round chimney pipe just above the roof flashing. The upper edge of the collar should be waterproofed with plastic sealer to prevent any water from leaking between the collar and chimney pipe. Part is tightened with screws or tabs after proper positioning. Selkirk SURE-TEMP Locking Band, Stainless Steel, 7 in Dia, Suitable for: Chimney Pipe Round collar fits lower end of suspended insulated chimney pipe to provide finished appearance. Used to attach T-DSA Smoke Pipe Adapter to lower end of chimney or to insulated Tee.
AmeriVent 6SWA Single Wall Adapter Sure-Temp 206791 Spark Arrestor Selkirk 208480 Finishing Collar
Included in ceiling support assembly, roof support assembly and tee assembly. Diamond shaped 1/2 in x 1 in mesh, 18-8 stainless steel. Fits same size round chimney top. Keeps foreign objects out of chimney. Round collar fits lower end of suspended insulated chimney pipe to provide finished appearance. Used to attach T-DSA Smoke Pipe Adapter to lower end of chimney or to insulated Tee.
Sure-Temp 206465 Fire Stop/Joist Shield WALL BAND                     Sure-Temp 208790 Spark Arrestor
Prevents or delays the rapid spread of fire (regardless of the cause) in a home or building. The sheet metal firestop prevents the chimney passageway from becoming an easy pathway for fire to spread from one floor to another. Selkirk Wall Band, Stainless Steel, 6 in Dia Diamond shaped 1/2 in x 1 in mesh, 18-8 stainless steel. Fits same size round chimney top. Keeps foreign objects out of chimney.
American Metal 6HS-SBA 3-Wall Wall Bracket Sure-Temp 208520 Wall Band Selkirk 207512 Adjustable Pitch Ceiling Plate
Bracket for supporting the chimney pipe offsets, securing outdoor chimney to exterior wall. Used along the wall to provide for 2 in clearance and assure stability. Useful for suspending offsets. Required at 8 ft or closer intervals to stabilize the chimney, wherever it is supported along a vertical wall. Provides a finished appearance where the chimney passes through a sloped ceiling. Matte black finish. Adjusts to multiple roof pitches. Covers 4 in space around chimney pipe (or 2 in further than the required clearance).
Ultra Temp 206450 Type A Locking Band Selkirk 206512 Adjustable Pitch Ceiling Plate American Metal 6FFU 3-Wall Round Roof Vent Flashing
Selkirk SURE-TEMP Locking Band, Stainless Steel, 6 in Dia, Suitable for: Chimney Pipe Provides a finished appearance where the chimney passes through a sloped ceiling. Matte black finish. Adjusts to multiple roof pitches. Covers 4 in space around chimney pipe (or 2 in further than the required clearance). Standard flashings fit various pitch roofs. Its double seamed construction protects from water leakage.
Selkirk 208512 Adjustable Pitch Ceiling Plate Sure-Temp 206400 Anchor Plate Selkirk 206240 Drip less Smoke Stove Pipe Adapter
Provides a finished appearance where the chimney passes through a sloped ceiling. Matte black finish. Adjusts to multiple roof pitches. Covers 4 in space around chimney pipe (or 2 in further than the required clearance). Provides a secure attachment for the chimney to smoke chamber outlet on masonry fireplaces, reducing footing loads and speeding construction. Stainless steel and heavy-gauge steel construction for long life. Retains chimney with a twist-lock connection. Selkirk Drip less Smoke Stove Pipe Adapter, 430 Stainless Steel, Dimensions: 15-3/4 In L
Sure-Temp 206435 Interior Resupport Selkirk 206242 Drip less Smoke Stove Pipe Adapter Sure-Temp 206463 Insulated Wall Thimble
Interior resupport assembly allows for two different methods of chimney resupport. The first method is used at the immediate section of chimney above the upper elbow of an offset. With the appropriate fire stop/joist shield (JS) in place, clamp the support band around chimney and attach with six-sheet metal screws. The second means of support is used primarily when the immediate sections of the upper offset do not pass through a joist area and resupport is necessary. The support band is clamped around the chimney immediately below a locking band. In both methods, the straps are nailed to suitable framing at two inch clearance. The 18 ft limit of supportable chimney length applies. Selkirk Drip less Smoke Stove Pipe Adapter, 316 Stainless Steel, Dimensions: 15-3/4 In L Selkirk SURE-TEMP Insulated Thimble, Wall Mounting
Ameri-Vent 10RSC Double Wall Round Storm Collar Selkirk 208240 Drip less Smoke Stove Pipe Adapter Sure-Temp 200420 Roof Support
Use with HS chimney roof flashing to insure water tight installation. Selkirk Drip less Smoke Stove Pipe Adapter, 430 Stainless Steel, Dimensions: 15-3/4 In L Fits all roof pitches and requires only simple framing. Brackets and mounting hardware only.
Sure-Temp 200250 Roof Support Selkirk A 206825 Adjustable Roof Flashing Selkirk A 207825 Adjustable Roof Flashing
This new design gives you the flexibility of securing the 5, 6, 7 or 8 in Dia chimney with a heavy-duty band. The band allows you to slide the installed length verticaly to properly position this section in the system. Installation requirements are the same as our standard RSP. The URSA can hold 30 ft of pipe total only 20 ft. Flashings are used to seal the opening where the chimney penetrates the roof and to divert rain and snow down from the roof and away from the chimney system.A series of adjustable flashings are available depending on your roof pitch. A flat and low pitch flashing is used to seal flat and low pitch roof (up to 2/12 pitch) openings. To determine your roof pitch, measure the number of inches from the end of a level ruler down to the roof. This is the rise for 12 in of run. A rise of 5 in is a 5/12 pitch. 4 in, a 4/12 pitch and more. Flashings are used to seal the opening where the chimney penetrates the roof and to divert rain and snow down from the roof and away from the chimney system.A series of adjustable flashings are available depending on your roof pitch. A flat and low pitch flashing is used to seal flat and low pitch roof (up to 2/12 pitch) openings. To determine your roof pitch, measure the number of inches from the end of a level ruler down to the roof. This is the rise for 12 in of run. A rise of 5 in is a 5/12 pitch. 4 in, a 4/12 pitch and more.
American Metal 8FFU 3-Wall Round Roof Vent Flashing Sure-Temp 206800 Round Type HT Chimney Topper Selkirk 207240 Drip less Smoke Stove Pipe Adapter
Standard flashings fit various pitch roofs. Its double seamed construction protects from water leakage. Part of the chimney system roof assembly, the round top is designed with a dome to exclude rain and leaves and a lower skirt to deflect wind for proper chimney draft. In the Sure-Temp-Type HT Chimney (5 in, 6 in, 7 in and 8 in sizes) the round top is designed with three legs that slide down over the outside of the chimney. A cinch band is then positioned over the legs and tightened to hold the top firmly in place. This design makes cap removal for cleaning a breeze. Selkirk Drip less Smoke Stove Pipe Adapter, 430 Stainless Steel, Dimensions: 15-3/4 In L
Sure-Temp 208463 Insulated Wall Thimble Sure-Temp 206430 Type HT Wall Support Kit Sure-Temp 208400 Anchor Plate
Selkirk SURE-TEMP Insulated Wall Thimble, Wall Mounting The Type HT wall support kit has been tested for use fully enclosed and has been designed in 5, 6, 7 and 8 in sizes to carry up to 60 ft of height at 2 in from wall. The capacity of the larger sizes, 10, 12 and 14 in, is 40 ft of chimney. The wall support is intended for use with the Insulated Tee as an interior or exterior support where the chimney has a lateral connection. Provides a secure attachment for the chimney to smoke chamber outlet on masonry fireplaces, reducing footing loads and speeding construction. Stainless steel and heavy-gauge steel construction for long life. Retains chimney with a twist-lock connection.
Sure-Temp 206490 Attic Insulation Shield Sure-Temp 207440 Roof Brace Kit Selkirk A 208825 Adjustable Roof Flashing
Used wherever a ceiling support, finish support, firestop or joist shield is installed below an open attic. Required to guard against the hazard of blown-in or blanket insulation filling any framed opening or contacting the chimney and possible storage of combustibles against the chimney. Used whenever there is a need to stabilize the chimney above the roof level. The purpose of the bracing is to hold the chimney against wind load and to prevent damage from static and sliding snow. It should be used, at a midpoint on the chimney. Bracket adjusts from 4 to 6 ft. Flashings are used to seal the opening where the chimney penetrates the roof and to divert rain and snow down from the roof and away from the chimney system.A series of adjustable flashings are available depending on your roof pitch. A flat and low pitch flashing is used to seal flat and low pitch roof (up to 2/12 pitch) openings. To determine your roof pitch, measure the number of inches from the end of a level ruler down to the roof. This is the rise for 12 in of run. A rise of 5 in is a 5/12 pitch. 4 in, a 4/12 pitch and more.
Sure-Temp 207800 Type HT Round Top Sure-Temp 206440 Roof Brace Kit Sure-Temp 207430 Type HT Wall Support Kit
Selkirk SURE-TEMP Type HT Round Top Used whenever there is a need to stabilize the chimney above the roof level. The purpose of the bracing is to hold the chimney against wind load and to prevent damage from static and sliding snow. It should be used, at a midpoint on the chimney. Bracket adjusts from 4 to 6 ft. The Type HT wall support kit has been tested for use fully enclosed and has been designed in 5, 6, 7 and 8 in sizes to carry up to 60 ft of height at 2 in from wall. The capacity of the larger sizes, 10, 12 and 14 in, is 40 ft of chimney. The wall support is intended for use with the Insulated Tee as an interior or exterior support where the chimney has a lateral connection.
Selkirk A 206830 Adjustable Roof Flashing Sure-Temp Ultra-Temp 207410 Square Ceiling Support Selkirk A 207830 Adjustable Roof Flashing
Flashings are used to seal the opening where the chimney penetrates the roof and to divert rain and snow down from the roof and away from the chimney system.A series of adjustable flashings are available depending on your roof pitch. A flat and low pitch flashing is used to seal flat and low pitch roof (up to 2/12 pitch) openings. To determine your roof pitch, measure the number of inches from the end of a level ruler down to the roof. This is the rise for 12 in of run. A rise of 5 in is a 5/12 pitch. 4 in, a 4/12 pitch and more. With proper framing, all ceiling supports provide at least 2 in minimum clearance to combustibles at the support level and can carry up to 50 ft of vertical chimney height. Flashings are used to seal the opening where the chimney penetrates the roof and to divert rain and snow down from the roof and away from the chimney system.A series of adjustable flashings are available depending on your roof pitch. A flat and low pitch flashing is used to seal flat and low pitch roof (up to 2/12 pitch) openings. To determine your roof pitch, measure the number of inches from the end of a level ruler down to the roof. This is the rise for 12 in of run. A rise of 5 in is a 5/12 pitch. 4 in, a 4/12 pitch and more.
Selkirk A 206815 Adjustable Roof Flashing Sure-Temp 208430 Type HT Wall Support Kit Selkirk A 208815 Adjustable Roof Flashing
Selkirk SURE-TEMP Premium Roof Flashing, Aluminum, Galvanized, 24-3/4 in OAL, 21 in OAW, Suitable for: 7 x 12 in Dia Pipe The Type HT wall support kit has been tested for use fully enclosed and has been designed in 5, 6, 7 and 8 in sizes to carry up to 60 ft of height at 2 in from wall. The capacity of the larger sizes, 10, 12 and 14 in, is 40 ft of chimney. The wall support is intended for use with the Insulated Tee as an interior or exterior support where the chimney has a lateral connection. Selkirk SURE-TEMP Premium Roof Flashing, Aluminum, 27-3/4 in OAL, 24 in OAW, Suitable for: 8 in Dia Pipe
American Metal 6HS-CSA 3-Wall Ceiling Support Assembly AmeriVent 8HS-WTP 3-Wall Chimney Wall Thimble American Metal 6HS-RCS Insulated Chimney Cap
A ceiling support assembly is used when a chimney is installed in a flat ceiling. Available in a black finish, the 6 and 8 in sizes fit between regular 16 in O.C ceiling joists and are cartoned with a stainless steel black single wall adapter. Used with tee branch and chimney section to provide proper clearance to combustible materials. Matte black painted surface for interior wall eliminates need for trim plate. The durable, all stainless steel constructed cap is designed to minimize downdraft and features its own spark arrestor and bird debris screen.
Sure-Temp 208440 Roof Brace Kit Sure-Temp 208800 Round Type HT Chimney Topper Sure-Temp 208490 Attic Insulation Shield
Used whenever there is a need to stabilize the chimney above the roof level. The purpose of the bracing is to hold the chimney against wind load and to prevent damage from static and sliding snow. It should be used, at a midpoint on the chimney. Bracket adjusts from 4 to 6 ft. Part of the chimney system roof assembly, the round top is designed with a dome to exclude rain and leaves and a lower skirt to deflect wind for proper chimney draft. In the Sure-Temp-Type HT Chimney (5 in, 6 in, 7 in and 8 in sizes) the round top is designed with three legs that slide down over the outside of the chimney. A cinch band is then positioned over the legs and tightened to hold the top firmly in place. This design makes cap removal for cleaning a breeze. Used wherever a ceiling support, finish support, firestop or joist shield is installed below an open attic. Required to guard against the hazard of blown-in or blanket insulation filling any framed opening or contacting the chimney and possible storage of combustibles against the chimney.
Selkirk A 208830 Adjustable Roof Flashing American Metal 8HS-CSA 3-Wall Ceiling Support Assembly Sure-Temp Ultra-Temp 206410 Square Ceiling Support
Flashings are used to seal the opening where the chimney penetrates the roof and to divert rain and snow down from the roof and away from the chimney system.A series of adjustable flashings are available depending on your roof pitch. A flat and low pitch flashing is used to seal flat and low pitch roof (up to 2/12 pitch) openings. To determine your roof pitch, measure the number of inches from the end of a level ruler down to the roof. This is the rise for 12 in of run. A rise of 5 in is a 5/12 pitch. 4 in, a 4/12 pitch and more. A ceiling support assembly is used when a chimney is installed in a flat ceiling. Available in a black finish, the 6 and 8 in sizes fit between regular 16 in O.C ceiling joists and are cartoned with a stainless steel black single wall adapter. With proper framing, all ceiling supports provide at least 2 in minimum clearance to combustibles at the support level and can carry up to 50 ft of vertical chimney height.
American Metal 6HS-RSA12 3-Wall Chimney Roof Support Sure-Temp Ultra-Temp 208410 Square Ceiling Support American Metal 8HS-RSA12 3-Wall Roof Support
For exposed-beam ceiling installations. Available in flat to 6/12 pitch (Standard) and for steeper pitches of 7/12 to 14/12. Can be used up to 22/12 with double wall connector. Use ceiling support when chimney is to be installed in standard ceiling. Contains stainless steel matte black single wall adaptor. With proper framing, all ceiling supports provide at least 2 in minimum clearance to combustibles at the support level and can carry up to 50 ft of vertical chimney height. For exposed-beam ceiling installations. Available in flat to 6/12 pitch (Standard) and for steeper pitches of 7/12 to 14/12. Can be used up to 22/12 with double wall connector. Use ceiling support when chimney is to be installed in standard ceiling. Contains stainless steel matte black single wall adaptor.
Sure-Temp 206420 Type HT Roof Support Kit AmeriVent 8HS-RCS 3-Wall Round Vent Cap Selkirk A 207835 Adjustable Roof Flashing
Contains one 18 in length of pipe, roof brackets and necessary hardware. Not for use with coal burning stoves. Round termination features its own built-in spark arrestor. Protects against rain, debris and birds entering chimney. Flashings are used to seal the opening where the chimney penetrates the roof and to divert rain and snow down from the roof and away from the chimney system.A series of adjustable flashings are available depending on your roof pitch. A flat and low pitch flashing is used to seal flat and low pitch roof (up to 2/12 pitch) openings. To determine your roof pitch, measure the number of inches from the end of a level ruler down to the roof. This is the rise for 12 in of run. A rise of 5 in is a 5/12 pitch. 4 in, a 4/12 pitch and more.
Selkirk 206100 Insulated Chimney Tee with Tee Cap American Metal 6HS-RKS 3 Wall Round Fuel Kit Sure-Temp 208420 Type HT Roof Support Kit
Used to start chimneys indoors or outdoors using a wall support assembly or a masonry pier. A length of insulated chimney pipe is attached to the tee snout, using a Locking Band, to pass safely through combustible walls. An insulated tee cap is included which can be removed from bottom opening for inspection and cleanout. Maximum height of chimney which can be supported by an insulated tee is 50 ft. Built to last with a system combining corrosion-resistant stainless steel and sturdy galvanized steel. It features a space-age ceramic fiber refractory blanket to withstand intermittent temperatures up to 2100 deg F, is noncombustible, thin and lightweight. It features the same small outer dimensions and is compatible with the AmeriVent Model FB. It is light enough to be easily installed by one man. Kit contains stainless steel cap, standard flashing, storm collar, ceiling support and single wall adaptor. Contains one 18 in length of pipe, roof brackets and necessary hardware. Not for use with coal burning stoves.
Selkirk 207100 Insulated Chimney Tee with Tee Cap Sure-Temp 206206 Type HT Insulated Elbow Kit Selkirk 208100 Insulated Chimney Tee with Tee Cap
Used to start chimneys indoors or outdoors using a wall support assembly or a masonry pier. A length of insulated chimney pipe is attached to the Tee snout, using a locking band, to pass safely through combustible walls. An insulated tee cap is included which can be removed from bottom opening for inspection and cleanout. Maximum height of chimney which can be supported by an insulated Tee is 50 ft. Can be used for fixed offsets of 15 deg slope or in pairs for offsets adjustable from zero to 30 deg slope. Greater angles are prohibited by UL standard 103 and by the terms of the product listing. Required locking bands (2 packaged with each elbow kit) allow 360 deg rotation and lock the components together in place at the exact offset required. Insulated elbows can be used at the same 2 in air space clearance as chimney sections. Includes 2 elbows, 2 locking bands and interior resupport. Used to start chimneys indoors or outdoors using a wall support assembly or a masonry pier. A length of insulated chimney pipe is attached to the Tee snout, using a locking band, to pass safely through combustible walls. An insulated tee cap is included which can be removed from bottom opening for inspection and cleanout. Maximum height of chimney which can be supported by an insulated Tee is 50 ft.
American Metal 8HS-RKS 3 Wall Round Fuel Kit Sure-Temp 206211 Type HT Insulated Elbow Kit Sure-Temp 206621 Pitched Ceiling Support Kit
Built to last with a system combining corrosion-resistant stainless steel and sturdy galvanized steel. It features a space-age ceramic fiber refractory blanket to withstand intermittent temperatures up to 2100 deg F, is noncombustible, thin and lightweight. It features the same small outer dimensions and is compatible with the AmeriVent Model FB. It is light enough to be easily installed by one man. Kit contains stainless steel cap, standard flashing, storm collar, ceiling support and single wall adaptor. Can be used for fixed offsets of 30 deg slope. Greater angles are prohibited by UL Standard 103 and by the terms of the product listing. Required Locking bands (2 packaged with each elbow kit) are to be used at each joint. Each offset must be resupported. Elbows rotate 360 deg to provide the exact orientation required. Insulated elbows can be used at the same 2 ft air space clearance as chimney sections. Kit includes 2 elbows, 2 locking bands and one interior resupport. The Pitched Ceiling Support Kit provides all necessary parts for a complete installation with the exception of the required insulated pipe lengths and adjustable flashing (AF). Selection of the Adjustable Flashing is determined by the pitch of your roof.
Sure-Temp 206620 Flat Ceiling Support Kit Sure-Temp 208211 Type HT Insulated Elbow Kit Sure-Temp 208621 Pitched Ceiling Support Kit
Provides the support package and termination parts for a chimney that is supported by a flat ceiling and passes through an attic area and penetrates a 2/12 to 6/12 pitch roof. Just add pipe lengths and the Flat Ceiling Support Kit (FCK) has all necessary parts for complete installation. However, depending upon your roof design and the position of your chimney on the roof, it may be necessary to install a roof brace kit to provide required support for your chimney above the roof. Can be used for fixed offsets of 30 deg slope. Greater angles are prohibited by UL Standard 103 and by the terms of the product listing. Required locking bands (2 packaged with each elbow kit) are to be used at each joint. Each offset must be resupported. Elbows rotate 360 deg to provide the exact orientation required. Insulated elbows can be used at the same 2 ft air space clearance as chimney sections. Kit Includes 2 elbows, 2 locking bands and one interior resupport. The Pitched Ceiling Support Kit provides all necessary parts for a complete installation with the exception of the required insulated pipe lengths and adjustable flashing (AF). Selection of the Adjustable Flashing is determined by the pitch of your roof.
Sure-Temp 208620 Flat Ceiling Support Kit Sure-Temp 206622 Thru-the-Wall Support Kit Sure-Temp 208622 Thru-the-Wall Support Kit
Provides the support package and termination parts for a chimney that is supported by a flat ceiling and passes through an attic area and penetrates a 2/12 to 6/12 pitch roof. Just add pipe lengths and the Flat Ceiling Support Kit (FCK) has all necessary parts for complete installation. However, depending upon your roof design and the position of your chimney on the roof, it may be necessary to install a roof brace kit to provide required support for your chimney above the roof. For a wall-supported chimney system with a horizontal connector passing through an exterior wall, connecting to a Tee and running verticaly up the exterior wall to termination above the roof line. The thru-the-wall support kit provides all necessary parts for a complete installation with the exception of required insulated pipe lengths to reach your desired chimney height. For a wall-supported chimney system with a horizontal connector passing through an exterior wall, connecting to a Tee and running verticaly up the exterior wall to termination above the roof line. The thru-the-wall support kit provides all necessary parts for a complete installation with the exception of required insulated pipe lengths to reach your desired chimney height.